Nivoscop
Mobile filling level gauge
for pipes and tanks
 
 
- Filling level of any fluid
in pipes and tanks
- Very good accuracy
- Deposits and obstructions in pipes
- Appropriate to all current pipes materials from DN50 and
wall thickness up to 12 mm (steel) respectively 25 mm (plastic)
- Contact-free measurement, for extreme applications
- Easy to use, no correction or calibration needed
- Undisturbed by foam, bubbles or vibrations
|
Technical specifications |
Measuring range
|
Filling level: | 0 mm bis 80 mm |
Nominal diameter: | ≥ DN50 |
Wall thickness: | ≤ 12 mm (steel) |
| ≤ 25 mm (plastic) |
|
Accuracy
|
≤ 5 mm for ≤ DN100
± 20 mm for filling level > 50 mm
or wall thickness > 8 mm
± 10 % of the nominal diameter for DN > 100
Sensitivity limit 10 mm
|
γ Source
|
Isotope 22Na
Activity: < 500 kBq
Half-life: 2,6 y
Activity bellow the radio protection limit.
|
Detector
|
CsI scintillation detector
ø 21 mm, length 60 mm
PIN-diode readout
|
Embedded computer
|
AMD ELAN520 - CPU 133 MHz - 16 MB SDRAM - 32 MB Flashdisk
|
Power supply
|
NiMH-battery, rechargeable Operation time: > 1 h
|
Dimensions and weight
|
Detector unit [cm]: 17 x 7,5 x 3,6
Analysis unit [cm]: 17,3 x 8,5 x 17,5
Complete weight: 2,9 kg
|
|
|
|